Specifications |
Max. Board Size
|
47 x 31.5″(1200 x 800mm)
|
Number of Probe
|
2 Front, 2 Rear
|
Min. Board Size
|
1.3 x 2.6″(35 x 65mm)
|
Max. Board Thickness for Clamping
|
0.511″(13mm)
|
Repeatable Accuracy
|
±0.000157″(±4µm)
|
Resolution
|
0.000236″(6µm)
|
Min. Pad Pitch†1
|
0.007087″(180µm)
|
Min. Pad Size†2
|
0.00314″(80µm)
|
Test Voltage of Resistance Measurement
|
Continuity test : 0-10V Isolation test : 250V(500V/1000V option)
|
Test Current of Resistance Measurement
|
Continuity test : 2.65 µA-125mA
|
Clamp System
|
Pneumatic
|
Number of CCD Camera
|
2 Front, 2 Rear
|
Monitor
|
included
|
Printer
|
internal
|
Air Requirements(Pressure, Consumption)
|
0.5MPa, 1.5gal/min.(5.7Ltr/min.)
|
Power Supply (Single Phase AC200-240V 50/60Hz)†3
|
15A
|
Weight
|
3480lbs.(1670kg)
|
Dimensions
|
 |
†1 When Probe (T96MC-PB-0R40) used. †2 When Probe (T96MC-PB-0B00) used. †3 Power Supply : There is a case incoming current about decuple of amperage rating might pass when power is on. Please choose breaker that will not cause any malfunction by this incoming current. [System Requirements] Control PC & Monitor [Software] EMMA2000 is standard, Ask our sales department about our optional software. [Probe Type] Users can choose one of different types of probes depending on tester models. Please ask our sales for specifications of each probe & PC. [Operating Conditions] 70-75°F (21-24°C), 30-70% relative humidity, non-condensing, no dust, no vibration, no corrosive gas. Please click here to view flyer for EMX12181(PDF:449KB) |