You are here: Home Products Mason Mason MU2000 SLA

Mason MU2000 SLA

Universal Tester : MU2000SLA

ITEM SPECIFICATION
Test point (Option) 184320(Max)
Test area 24″x19.2″(Max)
Density 70mil (Double density) or 100mil (Single density)
Fixture spec Mason rigid fixture can be selected to be compatible with other formats,Minimum diameter pin:0.25mm,Minimum distance of placing pins:12mil pitch.
CAM support software MUNet2000(Testpoint,fixture,net list support,etc.)
Net list format Mason MXG format (other format option)
Isolation test voltage 50V-300V±10%
Isolation test threshold 1 MO-100MO±10%
Continuity test 10O-100O±10%
Merged resistors test 10O-200KO±10%
Carbolic resistor test 10O-20KO±10%
Test speed 2500-4000 Point/sec.
Temperature and humidity 10-25°C less than 70% (No condensation)
Power supply AC380V±10% -phase 5 wires
Weight 2500kg (Manual) 3100kg (Automatic)
Size 1154mmx1983mmx2002mm (Manual)
5135mmx1983mmx2002mm (Automatic)

PDF Document Please click here to download the PDF for this specification.