MU2000S2a

ITEM SPECIFICATION
Test point 81920(Max)
Test area area 12.8″x(nx0.8″+6.4″) Min:12.8″x6.4″ Max:12.8″x16
Density 50 mil Quad-density / 70mil Double density
Fixture spec Mason rigid fixture can be selected to be compatible with other formats,Minimum diameter pin:0.15mm,Minimum distance of placing pins:12mil pitch.
CAM support software MUNet2000(Testpoint,fixture,net list support,etc.)
Net list format Mason MXG format (other format option)
Isolation test voltage 50V-300V
Isolation test threshold 1 MO-100MO
Continuity test 10O-1000O
Merged resistors test 1O-200KO
Test speed 2500-4000 Point/sec.
Automatic loading Option
Temperature and humidity 10-25°C less than 70% (No condensation)
Power supply AC380V±10% – phase 5 wires
Air supply 6-7kgf/cm2
Weight 1500kg(Manual) 2000kg(Automatic)
Size 1030x1180x1680(Manual) 3090x1180x1680(Automatic)

PDF Document Please click here to download the PDF for this specification.